All cylinders are shipped empty, except for LIFE Oxygen tanks.
This item does not qualify for free shipping.
The 300 Cu. Ft. T Steel Oxygen Cylinder with CGA-540 Valve is a high-capacity steel cylinder designed for oxygen storage applications where a larger stationary supply is preferred over smaller portable cylinders. With a nominal capacity of approximately 300 cubic feet, or 8,495 liters, this T-size cylinder can be used as a backup oxygen supply or as a source cylinder for compatible oxygen filling systems operated by properly trained personnel.
The cylinder is equipped with a CGA-540 oxygen valve, the threaded valve connection commonly used on larger high-pressure oxygen cylinders. A compatible CGA-540 regulator, manifold or approved oxygen system is required for use.
CPR Savers Part Number: 110-1861
Cylinder Size: T
Nominal Capacity: 300 cu. ft. / 8,495 liters
Material: Steel
Valve Connection: CGA-540
Shipping Condition: Empty
Important: This cylinder ships empty. Oxygen is not included.
High-Capacity Steel Oxygen Cylinder
A T-size cylinder provides substantially greater oxygen capacity than smaller portable medical oxygen cylinders. Its larger capacity can make it appropriate for facilities and organizations that need a stationary reserve supply or that use compatible oxygen filling equipment.
Because of its size and steel construction, this cylinder is best considered a high-capacity stationary or facility-use cylinder rather than a portable personal oxygen tank. Appropriate cylinder storage and handling equipment should be used.
300 Cu. Ft. T Cylinder Features
- Nominal 300 cubic foot capacity
- Provides approximately 8,495 liters of oxygen capacity when properly filled
- Steel cylinder construction
- T-size high-capacity cylinder
- Includes a CGA-540 oxygen valve
- Suitable for use with compatible CGA-540 oxygen regulators and systems
- Can serve as a high-capacity backup oxygen cylinder
- Can be used as a supply cylinder with compatible oxygen filling or transfill equipment when operated by qualified personnel
- Ships empty
What Is a CGA-540 Valve?
CGA-540 is a threaded valve connection used with high-pressure oxygen cylinders. Unlike the CGA-870 post-valve connection commonly found on smaller portable medical oxygen cylinders, CGA-540 is typically used on larger cylinders and requires a regulator or system specifically designed with a compatible CGA-540 inlet.
Do not assume that a regulator made for a smaller CGA-870 oxygen cylinder will fit this cylinder. Verify the regulator inlet connection before ordering accessories.
Backup Oxygen Supply
Large steel cylinders are useful when a greater reserve volume is needed in one cylinder. Depending on the facility and application, a T-size cylinder may be incorporated into a backup oxygen supply, emergency preparedness system or other properly designed oxygen setup.
The amount of operating time available from a filled cylinder depends on the actual fill level and the flow rate of the connected equipment. Always monitor cylinder pressure and follow the procedures established for your oxygen system.
Use with Oxygen Filling Systems
This cylinder may also be used as a source cylinder for compatible oxygen filling or transfill equipment. Oxygen transfer involves high-pressure gas and requires equipment specifically designed for the cylinder, valve connection and intended application.
Filling or transferring oxygen should only be performed using approved equipment and procedures by individuals who are properly trained and authorized to do so. Do not attempt to transfer oxygen using improvised fittings, adapters or equipment.
Ships Empty
All standard CPR Savers oxygen cylinders ship empty unless a product listing specifically states otherwise. This 300 cu. ft. T cylinder does not arrive filled with oxygen.
The cylinder must be filled by an appropriate oxygen or medical-gas supplier before use. Filling requirements, documentation and availability may vary by supplier and intended application, so confirm local filling requirements before purchasing.
Oxygen Cylinder Safety
Oxygen is a strong oxidizer and can cause materials to burn more rapidly. High-pressure oxygen cylinders should always be handled, stored and used according to applicable safety requirements and the instructions provided with the connected equipment.
- Keep the cylinder secured to prevent tipping or falling.
- Keep oxygen cylinders away from flames, sparks and excessive heat.
- Never allow oil, grease or petroleum-based products to contact oxygen valves, regulators or fittings.
- Use only regulators, valves, hoses and accessories intended and approved for oxygen service.
- Do not modify the valve or use unapproved adapters.
- Protect the cylinder valve from impact during handling and storage.
- Use and store compressed-gas cylinders in accordance with applicable facility, fire-code and gas-supplier requirements.
Choosing a Regulator for a CGA-540 Cylinder
A regulator used with this cylinder must have a CGA-540-compatible inlet connection and be rated for the intended oxygen application. Flow requirements and outlet connections also vary between systems, so valve compatibility alone does not determine whether a regulator is appropriate.
Browse CPR Savers' Medical Oxygen Regulators to compare available regulator configurations.
Secure Storage for Large Oxygen Cylinders
Because T cylinders are considerably larger than portable oxygen cylinders, proper storage is especially important. The cylinder should be kept upright and secured using storage equipment appropriate for its size and installation.
For compatible stands, racks, carts and other storage options, browse Oxygen Storage & Carts.
Explore More Oxygen Cylinders
CPR Savers carries oxygen cylinders in multiple capacities and valve configurations for portable, emergency and facility applications. Browse all Oxygen Tanks & Cylinders to compare available sizes and configurations.
300 Cu. Ft. T Steel Oxygen Cylinder FAQs
Does this cylinder come filled with oxygen?
No. This cylinder ships empty. Oxygen is not included and the cylinder must be filled by an appropriate oxygen or medical-gas supplier before use.
How much oxygen can this T cylinder hold?
The listed nominal capacity is 300 cubic feet, equivalent to approximately 8,495 liters of gaseous oxygen when properly filled.
What valve does this cylinder use?
The cylinder comes with a CGA-540 valve, a threaded connection commonly used on larger high-pressure oxygen cylinders.
Can I use a CGA-870 regulator with this cylinder?
No. A CGA-870 regulator is designed for a different valve connection commonly found on smaller medical oxygen cylinders. This T cylinder requires equipment with a compatible CGA-540 connection.
Can this cylinder be used as a backup oxygen supply?
Yes. Its large capacity makes it suitable for use as a backup oxygen cylinder when incorporated into a properly designed system using compatible regulators, storage equipment and other required components.
Can it be used with an oxygen filling system?
It can be used as a source cylinder with compatible oxygen filling or transfill systems designed for a CGA-540 cylinder. Oxygen transfer involves high-pressure gas and should only be performed by trained personnel using approved equipment and procedures.
Is this considered a portable oxygen cylinder?
This is a large T-size steel cylinder and is better suited to stationary, facility or high-capacity applications than routine portable use. Smaller aluminum and composite oxygen cylinders are generally better suited when portability is a primary requirement.
What type of regulator do I need?
The regulator must have a CGA-540 inlet and be approved for oxygen service. The correct flow range, outlet connection and pressure requirements depend on the equipment and application being supplied.
How should the cylinder be stored?
The cylinder should be secured to prevent tipping, protected from damage and kept away from heat, ignition sources, oil and grease. Use storage equipment appropriate for the cylinder size and follow applicable compressed-gas and facility safety requirements.